— Avviatori invertitori protetti da salvamotori MS132-K con morsetti a molla push-in Coordinamento tipo 1 e 2
Salvamotori
I >
IEC
Tipo 1)
Codice ABB
Intervallo di regolazione
Impost. corrente di cortocircuito
AC-3, 400 V Valore nominale di impiego potenza corrente kW A
istantanea nominale li
A
A
Tipo di coordinamento 1, AC-3, 16 kA or 50 kA, 400 V, 50/60 Hz 0.06 0.2 MS132-0.25K
1SAM350010R1002 1SAM350010R1003 1SAM350010R1004 1SAM350010R1004 1SAM350010R1005 1SAM350010R1006 1SAM350010R1006 1SAM350010R1007 1SAM350010R1008 1SAM350010R1008 1SAM350010R1009 1SAM350010R1010 1SAM350000R1010 1SAM350010R1012 1SAM350010R1011 1SAM350010R1014 1SAM350010R1015 1SAM350010R1002 1SAM350000R1003 1SAM350010R1004 1SAM350010R1004 1SAM350010R1005 1SAM350010R1006 1SAM350010R1006 1SAM350010R1007 1SAM350010R1008 1SAM350010R1008 1SAM350010R1009 1SAM350010R1010 1SAM350010R1010 1SAM350010R1012 1SAM350010R1011 1SAM350010R1014 1SAM350010R1015
0.16...0.25 0.25...0.40 0.40...0.63 0.40...0.63 0.63...1.00 1.00...1.60 1.00...1.60 1.60...2.50 2.50...4.00 2.50...4.00 4.00...6.30 6.30...10.0 6.30...10.0 8.00...12.0 10.0...16.0 20.0...25.0 25.0...32.0 0.16...0.25 0.25...0.40 0.40...0.63 0.40...0.63 0.63...1.00 1.00...1.60 1.00...1.60 1.60...2.50 2.50...4.00 2.50...4.00 4.00...6.30 6.30...10.0 6.30...10.0 8.00...12.0 10.0...16.0 20.0...25.0 25.0...32.0
3.13
0.09 0.12 0.18 0.25 0.37 0.55 0.75
0.3
MS132-0.4K MS132-0.63K MS132-0.63K MS132-1.0K MS132-1.6K MS132-1.6K MS132-2.5K MS132-4.0K MS132-4.0K MS132-6.3K MS132-10K MS132-10K MS132-12K MS132-16K MS132-25K
5
0.44
7.88 7.88 12.5
0.6
0.85
1.1 1.5 1.9 2.7 3.6 4.9 6.5 8.5
20 20
31.25
1.1 1.5 2.2
50 50
78.75
3
150 150 180 240 375 480
4
5.5
11.5 15.5
7.5
11
22 29
15
MS132-32K
Tipo di coordinamento 2, AC-3, 16 kA or 50 kA, 400 V, 50/60 Hz 0.06 0.2 MS132-0.25K
3.13
0.09 0.12 0.18 0.25 0.37 0.55 0.75
0.3
MS132-0.4K
5
0.44
MS132-0.63K MS132-0.63K MS132-1.0K MS132-1.6K MS132-1.6K MS132-2.5K MS132-4.0K MS132-4.0K MS132-6.3K MS132-10K MS132-10K MS132-12K MS132-16K MS132-25K MS132-32K
7.88 7.88 12.5
0.6
0.85
1.1 1.5 1.9 2.7 3.6 4.9 6.5 8.5
20 20
31.25
1.1 1.5 2.2
50 50
78.75
3 4
150 150 180 240 375 480
5.5 7.5
11.5 15.5
11 15
22 29
(1) Il salvamotore manuale MS116 può essere selezionato in base al range di regolazione della corrente indicato sulla linea di coordinamento, fino a: - 15 kW, 400 V - AC-3 a 16 kA - 4 kW, 400 V - AC-3 a 50 kA. (2) Per altre tensioni di comando vedere la “Tabella dei codici di tensione”. (3) I contattori tripolari AF38 possono essere selezionati per il coordinamento tipo 1, 16 kA e 50 kA, 18,5 kW, 400 V - AC-3 (BEA65-4 disponibile solo per AF40 ... AF65).