SACE TMAX XT UL/CSA LOW VOLTAGE MOLDED CASE C I RCUI T- BRE AKERS UL4 89 AND CSA C2 2 . 2 STANDARDS
4/16
— Accessories for Ekip Touch/Hi-Touch trip units
Connectivity Tmax XT circuit-breakers can be integrated perfectly into all automation and energy management systems to improve productivity and energy consumption and to carry out remote service. They can be equipped with communication units available for use with Modbus, Profibus, and DeviceNet™ protocols as well as with the modern Modbus TCP, Profinet and EtherNet/IP™ protocols. Furthermore, the integrated IEC 61850 communication module enables connection to automation systems widely used in medium voltage power distribution to create intelligent networks (Smart Grids). The modules are available in both solutions, internally and externally mounted. The internal modules are installed directly inside the circuit-breaker and the external modules can be easily installed directly on the terminal box or in the Ekip cartridge, even at a later date.Accurate measurements of current, voltage, power and energy are all avail- able by means of the communication modules. The trip units themselves can be used as multimeters that display the measurements available, or the Ekip Multimeter can be connected on the front of the switch- gear without the need for external instruments. All the functions are also accessible via the Internet, in complete safety. In addition, a full set of information on the plant and circuit-breaker can be made avail- able throughout the cloud via ABB Ability™ Energy and Asset Manager.
Circuit-breaker
Trip Unit Type
Internal modules
External modules with Ekip Cartridge
XT2-XT4
Switch-disconnector
Thermomag Ekip Dip Ekip LSI / LSIG
Internal Ekip COM STA
-
Internal Ekip COM LSI-LSIG
Ekip Touch/ Hi Touch Switch-disconnector Thermomag Ekip Dip Ekip Touch/ Hi Touch
Internal Ekip COM
External Ekip COM
XT5
Internal Ekip COM STA
Internal Ekip COM
External Ekip COM
Circuit-breaker
Trip Unit Type
Terminal box
XT7-XT7M
Switch-disconnector Ekip Dip Ekip Touch/ Hi Touch
-
External Ekip COM
Internal modules Available with several different communication protocols, the Ekip Com internal module is installed di- rectly inside the circuit-breaker. It allows the circuit-breaker to be integrated in a communication network for supervision and control. Ekip Com internal modules can be used for the XT2-XT4 and XT5. They can be connected to the trip unit when Ekip Touch is used. In other cases (for the Ekip Dip, thermal-magnetic trip unit, or switch-disconnector), the Modbus RTU and TCP, available in the STA version (Stand-Alone), can be still installed inside the circuit-breaker to provide information on the status of the circuit-breaker and re- mote control (adding the motor operator).
— XT5 Ekip Com TCP internal module
Protocols
Ekip Com Module
Ekip Touch/Hi-Touch
Ekip Dip, Thermal-magnetic unit, Switch Disconnector
Modbus RTU
Ekip Com Modbus RS-485 Ekip Com Modbus TCP
Modbus TCP/IP
Profinet
Ekip Com Profinet Ekip Com EthernNet Ekip Com IEC61850
- - -
EthernNet / IP
IEC61850