Tmax XT UL Catalogo [EN]

SACE TMAX XT UL/CSA LOW VOLTAGE MOLDED CASE C I RCUI T- BRE AKERS UL4 89 AND CSA C2 2 . 2 STANDARDS

7/20

— Signaling

250V AC/DC and 24V AC/DC auxiliary contacts are installed without the need for any screws. They are extremely easy to fit. Simply apply a slight pressure in the appropriate place. The following versions of auxiliary contacts are available: • cabled (AWG20 cable section -0.5mm 2 ): - for fixed/plug-in circuit-breakers with 3.28ft long cables; - for withdrawable circuit-breakers with fixed part and moving part connector; • not cabled: - for fixed/plug-in circuit-breakers with cables from AWG 20 up to AWG 15 cross-section. Auxiliary contacts are supplied for each circuit-breaker in the SACE XT family in various different com- binations, as shown in the table. The following items can be ordered to make the installation even more flexible: • an uncabled auxiliary contact can generate different signals (Q, SY or S52) according to the position where the circuit-breaker is installed; • an uncabled S51 auxiliary contact, which can be used for XT2, XT4, XT5 and XT6 circuit-breakers; • a cabled auxiliary contact, with unnumbered cables. It can generate different signals (Q, SY or S52) according to the position where the circuit-breaker is installed.

— Cabled auxiliary contact

— Uncabled auxiliary contact

XT1

XT2

XT3

XT4

Combinations of cabled auxiliary contacts with numbered cables

3/4p

3/4p

3/4p

3/4p

1Q 1SY 24V DC 3Q 1SY 24V DC 1S51 24V DC

F-P

F-P-W F-P-W F-P-W F-P-W F-P-W F-P-W F-P-W F-P-W

F-P F-P

F-P-W F-P-W F-P-W F-P-W F-P-W F-P-W F-P-W F-P-W

– –

–

1Q 1SY 250V AC/DC

F-P

F-P

— Cabled auxiliary contact for withdrawable circuit-breaker

2Q 2SY 1S51 250V AC/DC

– – – –

– –

3Q 2SY 250V AC/DC 3Q 1SY 250V AC/DC 1S51 250V AC/DC 2Q 1SY 250V AC/DC

F-P

–

F-P F-P

F-P F-P

F-P F-P

F-P F-P

3Q on the left 250V AC/DC

F = Fixed, P = Plug-in, W = Withdrawable

Combinations of cabled auxiliary contacts with numbered cables

XT5

XT6

Thermal-magnetic and Ekip Dip trip unit

Ekip Touch and Hi-Touch trip unit

1Q + 1SY on the left 24V DC

F-P

-

-

1Q + 1SY 24V DC 3Q + 1SY 24V DC

F-P-W F-P-W F-P-W F-P-W

F-P-W F-P-W F-P-W F-P-W

F-W F-W F-W F-W

1S51 24V DC 1S52 24V DC

1Q + 1SY on the left 250V AC/DC

F-P

-

-

1Q + 1SY 250V AC/DC 2Q + 1SY 250V AC/DC

F-P-W F-P-W F-P-W F-P-W F-P-W

F-P-W F-P-W F-P-W F-P-W F-P-W

F-W F-W F-W F-W F-W

3Q + 1SY 250V DC 1S51 250V AC/DC 1S52 250V AC/DC

F = Fixed, P = Plug-in, W = Withdrawable