Tmax XT UL Catalogo [EN]

SACE TMAX XT UL/CSA LOW VOLTAGE MOLDED CASE C I RCUI T- BRE AKERS UL4 89 AND CSA C2 2 . 2 STANDARDS

7/50

— Safety and protection

Padlocks and key locks Padlocks or key locks prevent the circuit-breaker from being closed and/or opened. They can be fitted: • directly on the front of the circuit-breaker; • on the rotary handle operating mechanism; • on the front for lever operating mechanism; • on the motor; • to the fixed part of withdrawable version, to prevent a moving part from being inserted; • on the front of the thermal-magnetic trip unit, to prevent the adjuster of the thermal part from being tampered with; • on the shutters of the fixed part. In the closed position, the locks do not prevent the mechanism from tripping due to the trip unit or a ser- vice release. Padlocks and keylock for circuit-breaker Type of lock Type of lock

— Fixed padlock in open position

— Fixed padlock in the open/closed position

Circuit- breaker

Optional/ standard supply

Position of circuit- breaker lock

Removability of key

PLL Fixed padlock device

XT1…XT4 Optional

OPEN/CLOSE Padlocks max 3 padlocks Ø 0.275 in stem (not supplied)

-

— Removable padlock in the open position - PLL

XT1…XT4 Optional

OPEN

Padlocks max 3 padlocks Ø 0.275 in stem (not supplied)

-

XT5, XT6 Optional

OPEN/CLOSE Padlocks max 3 padlocks Ø 0.315 in stem (not supplied)

-

XT5, XT6 Optional

OPEN

Padlocks max 3 padlocks Ø 0.315 in stem (not supplied) Padlocks max 3 padlocks Ø 0.315 in stem Padlocks max 3 padlocks Ø 0.157 in stem (not supplied) Padlocks max 2 padlocks Ø 0.315 in stem (not supplied) Padlocks max 1 padlocks Ø 0.275 in stem (not supplied) Padlocks max 3 padlocks Ø 0.275 in stem (not supplied) Padlocks max 3 padlocks Ø 0.315 in stem (not supplied) Ronis 1228 Same key (A, B, C, D type)

-

Optional

OPEN OPEN

- -

XT7 (1)

— Key lock

PLC Fixed padlock device

XT7 M Optional

Circuit- breaker

PLL Removable padlock device

XT1, XT3 Optional

OPEN

-

— Padlock in the open position - PLC

XT5, XT6 Optional

OPEN

-

XT1…XT7 Optional XT1…XT7 Optional XT1…XT7 Optional XT7 M Optional XT7 M Optional XT5…XT6 Optional

OPEN OPEN OPEN OPEN OPEN OPEN OPEN OPEN

OPEN OPEN

KLC Key lock (2)

Ronis 1228 Different key

Ronis 1228 Same key (A, B, C, D type) Giussani Same key (20005/6/7/8/9)

OPEN/CLOSE

OPEN OPEN OPEN OPEN OPEN

Giussani Different key

KLC Arrangement key lock

Kirk, Ronis 1104 and STI key lock

XT7

Optional

Kirk, Ronis 1104, STI and Castell key lock Kirk, Ronis 1104, STI and Castell (3) key lock This prevents the compartment door from being opened when the circuit-breaker is in the closed position (and with the circuit-breaker racked-in in case of withdrawable circuit- breakers). It also blocks the circuit-breaker from closing when the compartment door is open.

— Keylock - KLC

XT7 M Optional XT7, XT7 M Optional

DLC - Lock to prevent door

-

-

opening when the circuit-breaker is in the closed position

(1) For XT7, the PLL is direclty integrated in the plastic cover of the circuit-breaker (2) For the XT1, XT2, XT3 and XT4, the KLC is incompatible with the electrical accessories mounted on the third pole. (3) Factory mounted only

— Lock to prevent door opening - DLC