White paper
9
SCENARIO 3: SCHEMA APPLICATIVO PER EKIP UP USATO COME SISTEMA DI PROTEZIONE DI INTERFACCIA (CEI 0-16) E RICHIUSURA AUTOMATICA DI DISPOSITIVO DI INTERFACCIA (INTERRUTTORE O SEZIONATORE APERTO ABB) SCENARIO 3: APPLICATION DIAGRAM FOR EKIP UP AS INTERFACE PROTECTION SYSTEM (CEI 0-16) AND AUTOMATIC RECLOSING OF INTERFACE DEVICE (ABB AIR CIRCUIT BREAKER OR SWITCH-DISCONNECTOR)
TU1 1 A B
a b
TU1 2
a b
A B
OPERATING STATUS SHOWN THE CIRCUIT DIAGRAM IS FOR THE FOLLOWING CONDITIONS: - WITHDRAWABLE CIRCUIT BREAKER, OPEN AND RACKED-IN - CIRCUITS DE-ENERGIZED - EKIP UP NOT TRIPPED/IN ALARMS - MOTOR OPERATING MECHANISM WITH SPRINGS DISCHARGED CAPTION K51 = EKIP UP UNIT: IPD INTERFACE PROTECTION DEVICE DDI = LOW VOLTAGE CIRCUIT BREAKER (INTERFACE DEVICE) RTC= CIRCUIT BREAKER READY TO CLOSE CONTACT S43 = LOCAL / REMOTE SELECTOR SWITCH S44 = RECLOSING ENABLE SELECTOR SWITCH S51 = PROTECTIONS TRIPPED CONTACT ST = REMOTE DISCONNECTION PUSHBUTTON TR = MV/LV TRANSFORMER TU1/.. = LV VOLTAGE TRANSFORMERS TU2/.. = MV VOLTAGE TRANSFORMERS YC = CLOSING ACTUATOR YO = OPENING ACTUATOR YU = UNDERVOLTAGE OPENING ACTUATOR NOTE WARNING! SEE EKIP UP USER MANUAL (1SDH002003A1002) FOR DETAILS AND FUNCTIONAL LIMITS OF TERMINALS, SOCKETS CONTACTS AND ACCESORIES (1) SEE 1SDH002043A1001 FOR TEST CONNECTION AND CONFIGURATION (2) CONNECTION N INTENDED FOR CIRCUIT BREAKER 4P (3) ANTIFERRORESONANCE RESISTOR, VALUE IN DISCREPTION OF THE DESIGNER (4) SEE CEI 0-16 (5) USE GALVANICALLY ISOLATED POWER SUPPLY WITH 24VDC OUTPUT (CP-D 24 / 1.3 OR EQUIVALENT) (6) TV PROTECTION FUSE, VALUE IN DISCREPTION OF THE DESIGNER (7) CONNECT WHEN FORESEEN. DEFAULT CONNECTION TO OPENING RELEASE (8) IF RTC IS NOT PRESENT, CONNECT HC1 TO H11 (9) THE COMMAND ACTUATORS MUST COMPLIANT WITH EKIP SIGNALLING 4K FUNCTIONAL LIMITS (MAXIMUM VOLTAGE: 120VDC / 250VAC)
STATO DI FUNZIONAMENTO RAPPRESENTATO LO SCHEMA È RAPPRESENTATO NELLE SEGUENTI CONDIZIONI: - INTERRUTTORE IN ESECUZIONE ESTRAIBILE, APERTO E INSERITO - CIRCUITI IN ASSENZA DI TENSIONE - EKIP UP NON INTERVENUTO / IN ALLARME - COMANDO A MOTORE CON MOLLE SCARICHE LEGENDA K51 = UNITA' EKIP UP: SPI SISTEMA DI PROTEZIONE D'INTERFACCIA DDI = INTERRUTTORE BASSA TENSIONE (DISPOSITIVO D'INTERFACCIA) RTC= CONTATTO INTERRUTTORE PRONTO A CHIUDERE S43 = SELETTORE LOCALE / REMOTO S44 = SELETTORE ABILITAZIONE RICHIUSURA S51 = CONTATTO PROTEZIONI INTERVENUTE ST = PULSANTE PER TELEDISTACCO TR = TRASFORMATORE MT/BT TU1/.. = TRASFORMATORI DI TENSIONE BT TU2/.. = TRASFORMATORI DI TENSIONE MT YC = ATTUATORE DI CHIUSURA YO = ATTUATORE DI APERTURA YU = ATTUATORE DI APERTURA A MANCANZA TENSIONE NOTE ATTENZIONE! FARE RIFERIMENTO AL MANUALE D'USO EKIP UP (1SDH002003A1001) PER DETTAGLI E LIMITI FUNZIONALI DI MORSETTI, PRESE, CONTATTI, ACCESSORI (1) VEDI 1SDH002043A1001 PER I COLLEGAMENTI E LA CONFIGURAZIONE DI TEST (2) COLLEGAMENTI N PREVISTI CON INTERRUTTORE 4P (3) RESISTENZA ANTIFERRORISONANZA, VALORE A CURA DEL PROGETTISTA (4) SECONDO CEI 0-16 (5) USARE ALIMENTATORE GALVANICAMENTE ISOLATO CON USCITA 24VDC (CP-D 24/1.3 O EQUIVALENTE) (6) FUSIBILE DI PROTEZIONE DEL TV, VALORE A CURA DEL PROGETTISTA (7) COLLEGARE QUANDO PREVISTO. DI DEFAULT CONNESSO AD UNA BOBINA DI APERTURA (8) SE NON PRESENTE RTC, COLLEGARE HC1 A H11 (9) GLI ATTUATORI DI COMANDO DEVONO ESSERE COMPATIBILI CON I LIMITI FUNZIONALI DI EKIP SIGNALLING 4K (TENSIONE MASSIMA: 120VDC / 250VAC)
Powered by FlippingBook