SCHEMI ELETTRICI

3/9

Notes XT5-XT6 A) The presence of an auxiliary supply is re- quired for the local bus and zone selectivity functions (see Fig. 41-78). B) The undervoltage coil is provided for power supply branched on the supply side of the cir- B) La bobina di minima tensione viene fornita per l’alimentazione derivata a monte dell’in- terruttore o da una sorgente indipendente: è cuit-breaker or from an independent source: circuit-breaker can only close when coil is en- ergized (closing lock is obtained mechanically). C) Contacts S4/1 and S4/2 of Fig. 7-10-15 open cir- cuit when circuit-breaker is open and close it again when a manual closing command is im- parted by means of the rotary handle, in accor- dance with the Standards governing machine tools (however, circuit-breaker will not close if undervoltage release is not being supplied). D) Only for XT5 F-P. E) Only for XT5. G) If a three-pole fixed circuit-breaker with cur- rent transformer on the neutral conductor outside the circuit-breaker is used, the termi- nals of the TI/N transformer must be short-circuited when the circuit-breaker must be removed. H) "Galvanically separated converters" conform- ing to standards IEC 60950 (UL 1950) or equivalent must be used since an earthed Uaux is required. I) Mandatory in the presence of any sort of Ekip module. L) Only one application among Fig. 79...93-131- 132 can be supplied in the case of Ekip DIN Rail Cartridge Basic. In the case of Ekip DIN Rail Cartridge, up to three applications can be supplied among Fig. 79...93-131-132, taken once only. In addition, the Ekip Com module (if chosen) can be duplicated by choosing among Fig. 110...116. M) To ensure correct operation, the Ekip Supply module and at least one module must always be present. N) BELDEN 3105A cables or an equivalent type must be used. terruttori in esecuzione estraibile, il contatto S75I/2 dovrebbe essere connesso una sola volta a un modulo singolo. Note XT5-XT6 A) La presenza di un’alimentazione ausiliaria è necessaria per il bus locale e le funzioni di se- lettività di zona (vedere Fig. 41-78). permessa la chiusura dell’interruttore solo a bobina eccitata (il blocco della chiusura è re- alizzato meccanicamente). C) I contatti S4/1 e S4/2 rappresentati nelle fig- ure 7-10-15 aprono il circuito quando l’inter- ruttore si apre e lo richiudono quando viene impartito un comando di chiusura manuale mediante maniglia rotante, in accordo con le Norme relative alle macchine utensili (l’inter- ruttore comunque non si chiude se lo sganci- atore di minima tensione non è alimentato). D) Solo per XT5 F-P. E) Solo per XT5. G) Se si utilizza un interruttore fisso a tre poli con trasformatore di corrente sul conduttore neutro esterno, i terminali del trasformatore TI/N devono essere cortocircuitati nel caso in cui sia necessario rimuovere l’interruttore. H) Devono essere utilizzati dei "convertitori gal- vanicamente separati" conformi alle norme IEC 60950 (UL 1950) o equivalenti poiché è necessaria una Uaux a terra. I) Obbligatorio nel caso di un eventuale modulo Ekip. L) Soltanto una delle applicazioni illustrate nelle Fig. 79...93-131-132 può essere alimentata con una cartuccia base per barra Ekip DIN. Nel caso della cartuccia per barra Ekip DIN, pos- sono essere alimentate fino a tre delle appli- cazioni illustrate nelle Fig. 79...93-131-132, una sola volta. Inoltre, il modulo Ekip Com (se selezionato) può essere duplicato scegliendo tra le Fig. 110...116. M) Per garantire il corretto funzionamento, deve sempre essere presente il modulo Ekip Sup- ply e almeno un modulo. N) Devono essere usati cavi BELDEN 3105A o equivalenti. O) In presenza di diversi moduli Ekip Com con in-

0) When there are several Ekip Com modules with withdrawable circuit-breakers, contact 5751/2 must be connected once only to one single module. P) Auxiliary voltage Uaux allows all the functions of EKIP electronic protection relays to be ac- tivated. "Galvanically separated converters" conforming to standards IEC 60950 (UL 1950) or equivalent must be used since an earthed Uaux is required. Q) BELDEN 3105A cables or an equivalent type must be used. Maximum length 15 m. R) Recommended RJ45 cable: CAT6 STP. S) Consult "Technical Application Papers - vol. 9: Communication via BUS with ABB cir- cuit-breakers" for connection of the EIA RS485 serial line. T) Short-circuit terminals 1200 on to install a termination resistor on the Local Bus. U) Use Belden 3079A cables or equivalent. Con- sult White Paper 1SDC007412G0201 "Commu- nication with SACE Emax 2 circuit-breakers" for further details. U) Utilizzare cavi Belden 3084A o equivalenti. Consultare il White Paper 1SDC007412G0201 "Comunicazione con gli interruttori SACE Emax 2" per maggiori informazioni. Z) Ekip Supply non può essere usato per alimen- V) Use Belden 3084A cables or equivalent. Con- sult White Paper 1SDC007412G0201 "Commu- nication with SACE Emax 2 circuit-breakers" for further details. Z) Ekip Supply cannot be used to energize the electronic relay via terminals K1 and K2. AA) Consult Fig. 78 for the connection of W3 and W4. AB) Use two-pole shielded cable type BELDEN deve essere collegato a terra sul lato di in- gresso selettività (per la selettività di zona) o su entrambi i lati (per altre applicazioni). AC) La tensione secondaria massima nominale è di 120 V. 8762/8772 or equivalent. The shield must be earthed on the selectivity input side (for zone selectivity) or on both sides (for other appli- cations). AC) The rated maximum secondary voltage is 120V. AD) Use insulated cables for thermcouples such as PENTRONIC TEC/SITW-24F (Type TX) or equivalent. Maximum length 3 m. AD) Utilizzare cavi isolati per termocoppie come PENTRONIC TEC/SITW-24F (tipo TX) o equiv- alenti. Lunghezza massima 3 m. AE) Utilizzare cavi adatti fino a 3 m di lunghezza compatibili con l’ambiente di lavoro in cui si utilizza il sensore di corrente 4-20 mA. AG) Relè tipo TMG per XT5 soltanto AH) Designazione Connettore X .. -> X3 per XT5; X4 per XT6 AE) Use suitable cables up to 3 meters in length compatible with the workplace in which the 4-20mA current sensor is used AG) Relay type TMG for XT5 only AH) Designation Connector X .. -> X3 for XT5; X4 for XT6 P) La tensione ausiliaria Uaux consente l’at- tivazione di tutte le funzioni del relè di pro- tezione elettronica EKIP. Devono essere utiliz- zati dei "convertitori galvanicamente separati" conformi alle norme IEC 60950 (UL 1950) o equivalenti poiché è richiesta una Uaux a terra. Q) Devono essere usati cavi BELDEN 3105A o equivalenti. Lunghezza massima 15 m. R) Cavo RJ45 raccomandato: CAT6 STP. S) Consultare i “Documenti Applicazione Tecnica - vol. 9: Comunicazione tramite BUS con inter- ruttori ABB" per il collegamento della linea se- riale EIA RS485. T) Cortocircuitare i terminali 1200 per inserire una resistenza di terminazione sul Bus Locale. U) Utilizzare cavi Belden 3079A o equivalenti. Consultare il White Paper 1SDC007412G0201 "Comunicazione con gli interruttori SACE Emax 2" per maggiori informazioni. tare il relè elettronico con i terminali K1 e K2. AA) Vedere la Fig. 78 per il collegamento di W3 e W4. AB) Utilizzare un cavo schermato a due poli tipo BELDEN 8762/8772 o equivalente. Lo schermo

Powered by