System pro M compact. Interruttori e apparecchi modulari

41

— Interruttori magnetotermici S200 e S300 caratteristiche tecniche

S 200 M

S 200 M UC

S 300 P

SU 200 M

SU 200 DC

IEC/EN 60898-1, IEC/EN 60947-2 UL 1077, CSA 22.2 No. 235

IEC/EN 60898-2, IEC/EN 60947-2 UL 1077, CSA 22.2 No. 235

IEC/EN 60898-1, IEC/EN 60947-2 UL 1077, CSA 22.2 No. 235

IEC/EN 60947-2

UL 489, CSA22.2 No.5 1P, 2P, 3P, 4P

UL 489

1P, 2P, 3P, 4P

1P, 2P, 3P, 4P, 1P+N, 3P+N

1P, 2P

B, C, K, Z 0.2…63 A

B, C, D, K, Z

C, K, Z

K

0.2…63 A

0.2…25 A

1…63 A

0 / 50 / 60 Hz

50 / 60 Hz

DC

440 V c.a. (fase/fase)

-- --

2

1P: 230 V c.a., 220 V c.c. 2P: 400 V c.a., 440 V c.c. 3...4P: 400 V c.a.* 1P: 253 V c.a., 250 V c.c. 2P: 440 V c.a., 500 V c.c. 3...4P:440 V c.a.*

1P: 1+N: 240 V c.a., 72 V c.c. 2P: 415 V c.a., 125 V c.c. 3...4P: 3+N 415 V c.a.

--

1P: 1+N: 264 V c.a., 72 V c.c. 3...4P: 3+N: 462 V c.a. 125 V c.c.

--

-- --

10 kA

10 kA

≤ 25 A: 25 kA ≤ 32-40 A: 20 kA > 40 A: 15 kA

-- --

m)

6 kV

-- -- --

30 °C

1P: 253 V c.a., 220 V c.c. 2...4P: 440 V c.a., 440 V c.c.

1P: 240 V c.a.; 1P+N: 240 V c.a.; 2...4P: 415 V c.a.; 3P+N: 415 V c.a. 1P: 264 V c.a.; 1P+N: 264 V c.a.; 2P...4P: 462 V c.a.; 3P+N: 462 V c.a.;

1P: 230 V c.a. 2...4P: 400 V c.a.

--

1P: 266 V c.a., 250 V c.c. 2...4P: 462 V c.a., 500 V c.c.

1P: 253/440 V c.a.; 2...4P: 440 V c.a.

--

1P: 72 V c.c.; 2P: 125 V c.c.

12 V c.a.

-- --

15 kA

≤ 40 A: 10 kA c.a.; 10 kA c.c. > 40 A: 6 kA c.a.; 10 kA c.c. ≤ 40 A: 7,5 kA c.a.; 10 kA c.c. > 40 A: 6 kA(AC; 10 kA c.c.

25 kA

10 kA

≤ 40 A: 11.2 kA 50, 63 A: 7.5 kA

≤ 25 A: 12.5 kA ≤ 32…40 A: 10 kA > 40 A: 7.5 kA

7.5 kA

--

m)

6 kV

--

-- -- --

B, C: 55 °C; K, Z: 20 °C

B,C,D: 55°C; K,Z: 40°C

C, K, Z: 20°C

In < 32A: 20,000 ops (c.a.), In ≥ 32A: 10,000 manov. (c.a.); 1,500 manov. (c.c.);

In < 32A: 20,000 ops (c.a.), In ≥ 32A: 10,000 ops (c.a.); 1,500 ops (c.c.); (1 cycle 2s - ON, 13s - OFF, In ≤ 32A), (1 cyle 2s - ON, 28s - OFF, In ≥ 32A)