ABB PROTEZIONE E CONTROLLO DEL MOTORE
10/6
— Avviatori diretti (DOL) protetti da salvamotori MS Coordinamento tipo 1
Coordinamento tipo 1 o 2, AC-3, 16 kA o 50 kA, 400 V, 50/60 Hz Salvamotori Contattori
Accessori
I >
BEA..-4
CA4-10
IEC
Tipo (1)
Codice ordine
Range di regolazione corrente
Tipo (3)
Codice ordine
Regolazioni di corrente consentite
Corrente di intervento magnetico
Tipo
Codice ordine
Tensione nominale del circuito di comando Uc min. ... Uc max. (2)
AC-3, 400 V Valore nominale di impiego potenza corrente kW A
A
A
V 50/60 Hz V c.c.
A
0,06 0,2
MS132-0.25 1SAM350000R1002 0,16...0,25 2,44
24...60
20...60 (5) AF09Z-30-10-11 1SBL136001R1110 0,25
BEA16-4 1SBN081306T1000
100...250 100...250 AF09-30-10-13 1SBL137001R1310
0,09 0,3
MS132-0.4 1SAM350000R1003 0,25...0,40 3,9
24...60
20...60 (5) AF09Z-30-10-11 1SBL136001R1110 0,4
100...250 100...250 AF09-30-10-13 1SBL137001R1310
0,12 0,44
MS132-0.63 1SAM350000R1004 0,40...0,63 6,14
24...60
20...60 AF09Z-30-10-11 1SBL136001R1110 0,63
100...250 100...250 AF09-30-10-13 1SBL137001R1310
0,18 0,6
MS132-0.63 1SAM350000R1004 0,40...0,63 6,14
24...60
20...60 AF09Z-30-10-11 1SBL136001R1110 0,63
100...250 100...250 AF09-30-10-13 1SBL137001R1310 20...60 AF09Z-30-10-11 1SBL136001R1110 1 100...250 100...250 AF09-30-10-13 1SBL137001R1310 24...60
0,25 0,85
MS132-1.0 1SAM350000R1005 0,63...1,00 11,5
0,37 1,1
MS132-1.6 1SAM350000R1006 1,00...1,60 18,4
24...60
20...60 AF09Z-30-10-11 1SBL136001R1110 1,6
100...250 100...250 AF09-30-10-13 1SBL137001R1310
0,55 1,5
MS132-1.6 1SAM350000R1006 1,00...1,60 18,4
24...60
20...60 AF09Z-30-10-11 1SBL136001R1110 1,6
100...250 100...250 AF09-30-10-13 1SBL137001R1310
0,75 1,9
MS132-2.5 1SAM350000R1007 1,60...2,50 28,75
24...60
20...60 AF09Z-30-10-11 1SBL136001R1110 2,5
100...250 100...250 AF09-30-10-13 1SBL137001R1310 20...60 AF09Z-30-10-11 1SBL136001R1110 4 100...250 100...250 AF09-30-10-13 1SBL137001R1310 24...60 24...60 20...60 AF09Z-30-10-11 1SBL136001R1110 4 100...250 100...250 AF09-30-10-13 1SBL137001R1310
1,1
2,7
MS132-4.0 1SAM350000R1008 2,50...4,00 50
1,5
3,6
MS132-4.0 1SAM350000R1008 2,50...4,00 50
2,2
4,9
MS132-6.3 1SAM350000R1009 4,00...6,30 78,75
24...60
20...60 AF09Z-30-10-11 1SBL136001R1110 6,3
100...250 100...250 AF09-30-10-13 1SBL137001R1310 20...60 AF09Z-30-10-11 1SBL136001R1110 9 100...250 100...250 AF09-30-10-13 1SBL137001R1310 24...60 24...60 20...60 AF09Z-30-10-11 1SBL136001R1110 9 100...250 100...250 AF09-30-10-13 1SBL137001R1310
3
6,5
MS132-10 1SAM350000R1010 6,30...10,0 150
4
8,5
MS132-10 1SAM350000R1010 6,30...10,0 150
5,5
11,5
MS132-12 1SAM350000R1012 8,00...12,0 180
24...60
20...60 AF12Z-30-10-11 1SBL156001R1110 12
100...250 100...250 AF12-30-10-13 1SBL157001R1310
7,5
15,5
MS132-16 1SAM350000R1011 10,0...16,0 240
24...60
20...60 AF16Z-30-10-11 1SBL176001R1110 16
100...250 100...250 AF16-30-10-13 1SBL177001R1310
1SBN082306T2000 1SBN010110R1010
11
22
MS132-25 1SAM350000R1014 20,0...25,0 375
24...60
20...60 AF26Z-30-00-11 1SBL236001R1100 25
100...250 100...250 AF26-30-00-13 1SBL237001R1300 20...60 AF30Z-30-00-11 1SBL276001R1100 32 100...250 100...250 AF30-30-00-13 1SBL277001R1300 24...60
BEA38-4 + CA4-10 BEA65-4 BPR65-4 (4) CA4-10
15
29
MS132-32 1SAM350000R1015 25,0...32,0 480
1SBN083406R1000 1SBN113405R1000
18,5 35
MS165-42 1SAM451000R1015 30,0…42,0 630
24…60
20…60 AF40-30-00-11 1SBL347001R1100 40
100...250 100...250 AF40-30-00-13 1SBL347001R1300
22
41
MS165-54 1SAM451000R1016 40,0…54,0 810
24…60
20…60 AF52-30-00-11 1SBL367001R1100 53
1SBN010110R1010
100...250 100...250 AF52-30-00-13 1SBL367001R1300
30
55
MS165-65 1SAM451000R1017 52,0…65,0 975
24…60 20…60 AF65-30-00-11 1SBL387001R1100 65 100...250 100...250 AF65-30-00-13 1SBL387001R1300 20…60 AF80-30-00-11 1SBL397001R1100 75 100...250 100...250 AF80-30-00-13 1SBL397001R1300 24…60 24…60 20…60 AF96-30-00-11 1SBL407001R1100 90 100...250 100...250 AF96-30-00-13 1SBL407001R1300
37
66
MS495-75 1SAM550000R1008 57,0…75,0 975
45
80
MS495-90 1SAM550000R1009 70,0…90,0 1170
(1) Il salvamotore MS116 può essere selezionato in base al range di regolazione della corrente indicato sulla linea di coordinamento, fino a: - 15 kW, 400 V - AC-3 a 16 kA - 4 kW, 400 V - AC-3 at50 kA. (2) Per altre tensioni di comando vedere la “Tabella dei codici di tensione”
(3) I contattori tripolari AF38 possono essere selezionati per il coordinamento tipo 1, 16 kA e 50 kA, 18.5 kW, 400 V - AC-3 (BEA65-4 disponibile solo per AF40 ... AF65). (4) Per montaggio diretto su due guide 35 mm di MS165 con AF40 ... AF65: BEA65-4 deve essere associato a BPR65-4 fissato sulla base del contattore. Valido per MS165 prodotti dopo la settimana 31, 2016 (codice data > 16114). (5) AF ... -11 non adatti per controllo diretto da uscita PLC.
Powered by FlippingBook