SACE TMAX XT UL/CSA LOW VOLTAGE MOLDED CASE C I RCUI T- BRE AKERS UL4 89 AND CSA C2 2 . 2 STANDARDS
4/18
— Accessories for Ekip Touch/Hi-Touch trip units
External modules These Ekip Commodules, as well as the internal modules, allow integration in any communication network. They can be used on the XT2, XT4 and XT5 with an Ekip Touch/Hi-Touch trip unit by using the Ekip Cartridge. On the XT7 and XT7 M with an Ekip Touch/Hi-Touch trip unit, they can be mounted directly on the terminal box. Several modules can be used simultaneously enabling systems with different protocols, but also, in case of high reliability requirements, Ekip Com R modules can be installed to guarantee system redundancy. The Modbus RTU, Profibus-DP and DeviceNet™modules contain a terminating resistor and two dip switches for optional activation to terminate the serial network or bus. The Profibus-DP module also contains a polariza- tion resistor and two dip switches for its activation. When used on the XT7 and XT7 M, communication can be maintained with withdrawable circuit-breakers, even while they remain in the racked-out position, by us- ing Ekip AUP auxiliary position contacts and Ekip RTC ready to close circuit-breaker contacts.
— Communication module
Protocols
Ekip Com Module
Ekip Touch/Hi-Touch
Modbus RTU Modbus TCP Profibus-DP
Ekip Com Modbus RS-485 Ekip Com Modbus TCP
Ekip Com Profibus Ekip Com Profinet Ekip Com Ethernet Ekip Com DeviceNet Ekip Com IEC 61850
Profinet
Ethernet / IP
DeviceNet IEC 61850
Ekip Cartridge The external device connected directly to the Ekip Touch trip unit of XT2, XT4 and XT5 allows most of the connectivity modules to be used including: the Ekip Supply, Ekip Com, Ekip Link, Ekip 3T ,Ekip Signaling 2K and Ekip Synchro check. It is always necessary to install the Ekip Supply module. The Ekip Cartridge is available in two different versions: with 2 slots (1 Ekip Supply + 1 module) or with 4 slots (1 Ekip Supply + 3 modules). If needed, when circuit-breakers in the withdrawable version are used, it is possible to connect the posi- tion AUP contacts to the related pins of the cartridge to avoid failure messages on the communication channel. The cartridge can be installed on a DIN-rail everywhere in the panel. The cable that connects the trip unit with the Ekip Cartridge is 1m long. The external device can be also directly connected through the cable available with the new Slim Micro I/O avoiding the usage of a side connector with the trip unit.
24V/CAN
— Ekip Cartridge
Powered by FlippingBook