Tmax XT UL Catalogo [EN]

4/19

COMMUNI CAT ION AND CONNECT I V I T Y

Ekip Power Supply The Ekip Supply module supplies all Ekip trip units and modules present on the Ekip Cartridge or terminal box of the circuit-breaker with several auxiliary power sources (in AC or DC) available in the switchgear. The module permits the installation of the other advanced modules. It can be field installed at any time. Two versions are available according to the control voltage: • Ekip Supply 110-240V AC/DC • Ekip Supply 24-48V DC

— Ekip Power Supply

Ekip Link The Ekip Link module enables the Tmax XT circuit-breaker to be connected to an ABB communication sys- tem for locally supervising switchgear. It is available in both inside-breaker and external cartridge versions. It is available as: • an inside-breaker version for XT2, XT4, and XT5 sizes • a cartridge and terminal box mounted version for XT2, XT4, XT5, XT7 and XT7 M sizes.

— Ekip Link

Ekip Com Hub The Ekip Com Hub is the new communication module for cloud-connectivity. A circuit-breaker equipped with Ekip Com Hub can establish a connection with an ABB Ability™ Energy and Asset Manager for the low-voltage power distribution panel. This dedicated module is available in two versions: the inside-breaker (for XT2, XT4 and XT5 sizes) and the cartridge/ terminal box mounted versions (for XT2, XT4, XT5, XT7 and XT7 M sizes), even when other mod - ules are present. For further information related to the ABB Ability™ Energy and Asset Manager, please visit the dedicated website at http://new.abb.com/low-voltage/launches/ekip-smartvision. In order to ensure cybersecurity of the device, the Ekip Com Hub has loaded a Certificate from a Trusted Authority. Ekip Com Hub has to be connected to the external network in order to refresh the Cybersercu- rity Certificate and have it always up to date. In case of long-term disconnections from the network, more than 6 months (e.g. module in stock or physically disconnected), the correct functioning of Ekip Com Hub can be inhibited from the cybersecurity measures in place. It is recommended to keep the module con- nected or periodically connect it (e.g. in stock or physically disconnected) to the external network. Ekip Com Actuator The Ekip Com Actuator module enables the XT7 M circuit-breakers to be opened and closed remotely. The Ekip com Actuator is optional and can be ordered for all Ekip Touch/Hi-Touch trip units equipped with Ekip Com or Ekip Link modules. The Ekip Com Actuator is installed on the front of the circuit-breaker in the right-hand accessories area.

— Ekip Com Hub

— Ekip Com Actuator

Powered by