SACE EMAX 2 NEW LOW VOLTAGE POWER C I RCUI T BRE AKERS TO ANS I C37 / UL 1066 / CSA STANDARDS
6/4
— Accessories for circuit breakers
SACE Emax 2 circuit-breakers offer a wide range of accessories developed to meet the application and
installation requirements of every customer.
Automatic circuit-breaker
Switch-disconnector
E1.2
E2.2 - E4.2 - E6.2 E1.2
E2.2 - E4.2 - E6.2
Signalling Standard open/closed auxiliary contacts - AUX 4Q
/
/
/
/ / /
Open/closed auxiliary contacts - AUX 6Q Open/closed auxiliary contacts- AUX 15Q Auxiliary position contacts - AUP Ready to close signalling contact - RTC
-
/ /
-
/
/
/
/
/
/
TU Reset mechanical signalling of the tripping of protection trip unit - TU Reset Contact signalling tripping of Ekip protection trip unit - S51 Second contact signalling tripping of Ekip protection trip unit - S51/2 Contact signalling loaded springs – S33 M/2 (supplied with Motor)
/ /
/ /
- - -
- - -
-
/ /
/
/
/
Control Opening and closing release - YO/YC
/ / / / / / /
/ / / / / / /
/ / / / /
/ / / / /
Second opening and closing release - YO2/YC2
Undervoltage release - YU
Electronic time-delay device for undervoltage release - UVD
Motor - M
Remote reset - YR
-
-
Opening and closing release test unit - YO/YC Test Unit Safety Key lock and padlock in open position - KLC and PLC
/
/
/
/
/
/
Key lock and padlock in racked-in / test / racked-out position - KLP and PLP Shutter lock - SL Fail Safe Lock for racking-out mechanism with circuit-breaker in closed position Lock for racking in / racking out the mobile part when the door is open - DLR Lock to prevent door opening when circuit-breaker is in racked-in / test position - DLP Lock to prevent door opening when circuit-breaker is in closed position - DLC
-
-
-
-
/
/
/
/
Anti-insertion lock
/
/
/
/
Mechanical operation counter - MOC
/
/
/
/
Protection devices Protection device for opening and closing pushbuttons - PBC
/
/
/
/
IP30 Protection IP54 Protection
/
/
/
/
/ / /
/
/
/
Terminal covers - HTC / LTC
-
-
-
Separators - PB
/
/
/
Connections Orientable rear terminal - HR/VR
/
/
/
/
Front terminal - F
/ /
/ /
Other configurations
/
/
Interlocks and switching devices Mechanical interlock - MI Automatic transfer switches - ATS **
/ /
/
/ /
/
/ /
/
/ /
/
Standard accessory for fixed circuit-breaker Accessory on request for fixed circuit-breaker Standard accessory for mobile part
Accessory on request for mobile part Standard accessory for fixed part
Accessory on request for fixed part
*
Only closing release YC
** IEC only
Powered by FlippingBook