Tmax XT UL Caratteristiche Tecniche [EN]

INSTALL AT ION

1/7

XT4 - TMF and TMA 30°C

40°C

50°C

60°C

70°C

In [A]

MIN [A]

MAX [A]

MIN [A]

MAX [A]

MIN [A]

MAX [A]

MIN [A]

MAX [A]

MIN [A]

MAX [A]

80 90

60 67 74 83 94

86 95

56 63 70 77 88

80 90

52 60 67 71 81 98

74 86 95

46 54 60 65 74 90

66 77 85 92

41 47 53 59 67 85 98

58 68 75 84 95

100 110 125 150 175 200 225 250

106 118 134 158 184 210 241 262

100 110 125 150 175 200 225 250

101 115 141 166 190 208 240

105 128 153 175 190 230

110 129 147 168 183

105 123 140 158 175

122 140 160 170 220

116 133 146 168

107 123 133 161

112 119 154

XT5 - TMA

30°C

40°C

50°C

60°C

70°C

In [A]

MIN [A]

MAX [A]

MIN [A]

MAX [A]

MIN [A]

MAX [A]

MIN [A]

MAX [A]

MIN [A]

MAX [A]

300 400 500 600

220 310 375 440

314 420 535 630

210 280 350 420

300 400 500 600

200 260 330 395

286 380 470 572

187 240 305 345

267 350 435 534

165 225 280 300

235 320 400 500

XT6 - TMA

30°C

40°C

50°C

60°C

70°C

In [A]

MIN [A]

MAX [A]

MIN [A]

MAX [A]

MIN [A]

MAX [A]

MIN [A]

MAX [A]

MIN [A]

MAX [A]

600 800

459 603

655 861

420 560

600 800

373 501

533 716

358 467

512 668

245 310

490 620

XT5 - TMG

30°C

40°C

50°C

60°C

70°C

In [A]

MIN [A]

MAX [A]

MIN [A]

MAX [A]

MIN [A]

MAX [A]

MIN [A]

MAX [A]

MIN [A]

MAX [A]

300 400 500 600

220 310 375 440

314 420 535 630

210 280 350 420

300 400 500 600

200 260 330 395

286 380 470 572

187 240 305 345

267 350 435 534

165 225 280 300

235 320 400 500

Powered by